Analog Oscilloscopes

100MHz - Delayed Sweep

Model S-1390

Delayed Sweep & Dual Trace

Features

bullet

1mV/DIV Sensitivity.

bullet

Sweep to 2ns/DIV

bullet

Z Axis Input.

bullet

Single Sweep.

bullet

Dust Cover Included.

bullet

2 Free x1, x10 Probes

 
Specifications
Vertical Amplifiers (CH 1 and CH 2) Horixontal Amplifier (continued)
Sensitivity:  5mV/div - 5V/div (x1 mode).
                  1mV/div - 1V/div (x5 mode).
Attenuator: 1-2-5 sequence, 10 step attenuator plus   vernier control.
Rise Time: 5.8ns (S-1360), 3.5ns (S-1390).
Over Shoot: Less than 5%.
Input Impedance: 1MΩ ±2%, 25pF ±10%.
Max Input Voltage: 400V (DC + AC peak).
Operating Modes: CH1, CH2, DUAL(ALT or CHOP) and ADD.
Chop Frequency: Approximately 500kHz.
Algebraic Addition: CH 1 + CH 2, CH 1 - CH 2.
Inverter: CH 2 only.
Polarity Reversal: CH 2 only
Bandwidth: DC - 1MHz(-3dB).

X-Y Phase Difference: Approximately 3° at 50kHz.

Horizontal Amplifier Sweep System
X-Y Mode: Switch selectable using X-Y switch
          CH 1: X axis.
          CH 2: Y axis.
Accuracy: Y axis±3%, X axis±6%
Sweep Display Mode: Main, Mix, Delay
Hold Off Time: 5:1 continuously variable (0.1µs/div).
Main Sweep

Sweep Speed:
S-1360: 0.1µs/div - 2s/div in 1-2-5 sequence, 23 steps
S-1390: 20ns/div - 0.5s/div in 1-2-5 sequence, 23 steps
Accuracy: ±3%
Variable Time Control: 5:1, uncalibrated, continuously variable between steps.
Sweep Magnification:
10X, ±10%, extend sweep speed up to 10ns/div (S-1360).
10X, ±10%, extend sweep speed up to 2ns/div (S-1390).
 

Delayed Sweep Component Tester (S-1360 only)
Sweep Speed:
S-1360: 0.1µs/div - 2s/div in 1-2-5 sequence, 23 steps.
S-1390: 20ns/div - 0.5s/div in 1-2-5 sequence, 23 steps.
Acccuracy: ±3%
Delay Time Position: Varaiable control to locate desirable waveform for extending.
Test Voltage: Max. 6Vms (open circuit).
Test Current: Max. 11mA (shorted).
Test Frequency: Line Frequency.
Components: Capacitor, Inductor, Diode, Transistor, Zener etc.
Trigger CH 2 Output
Trigger Coupling: AUTO, NORM, TV-V, TV-H (S-1360).
AC, TV-V, TV-H, LINE (S-1390)
Trigger Source: CH 1, CH2, ALT (V MODE), LINE, EXT.
Slope: ±
Output Level: 100mV/DIV (no load). 50mv/div (50Ω load).
Bandwidth: 20Hz - 20MHz (-3dB).
Trigger Sensitivity (S-1360/S-1390) Other Specifications
Coupling Bandwidth Internal External CRT:  Type: Rectangular with internal graticule.
        Display Area: 8 x 10 div (1div = 1 cm).
        Accelerating Voltage: 12kV (S-1360), 14kV (S-1390).
        Phosphor: P31
Z Modulation: Positive TTL signal, low level blank intensity at any intensity, high level unblank any intensity.
Trace Rotation: Adjustable front panel.
Calibrator: Square wave 1kHz, 2.0Vpp±3% (S-1360)
                Square wave 1kHz, 0.5Vpp (S-1390)
Power requirements: 115, 230VAC±10%, 50/60Hz.
Power Consumption: Approximately 55 watts
Dimensions: 5 1/4" (H) x 12 3/4" (W) x 15 5/8" (D).
New Weight: S-1360: 17.2lbs (7.8kgs) S-1390: 18.7lbs (8.5kgs).
Accessories Supplied: Two x1, x10 probes, schematic diagram & parts list, AC power cord, spare fuse and dust cover.
TV-V DC- 1kHz 1.0 div 0.1Vpp
TV-H 1kHz - 100kHz 1.0 div 0.1Vpp
AUTO 100Hz -60/100MHz 1.5/2.0 div 0.1/0.2Vpp
NORM 100Hz -60/100MHz 1.5/2.0 div 0.1/0.2Vpp